Benefits from a Complete Product Solution
| |
Multi-Use: Used for BioThreat Detection and Pandemic
BioSurveillance. |
|
|
Easy-to-Use: Automated protocol requires limited hands-on time and training. |
| |
Fully Automated: Sample prep, amplification, identification,
and reporting. |
|
Network: Interoperable with global information grid. |
| |
Single Instrument Integration: Reduce the amount of equipment and consumables. |
|
Quick Test Times: Results in 1 hour. |
| |
Freeze-dried Reagents: Room temperature stable. |
|
More BioThreat Targets: Test 17 pathogens in one run. |
| |
More Sample Types:Integrated sample prep removes
PCR inhibitors and allows BioThreat detection in challenging environmental sample types such as soil and clay. |
Setting up the FilmArray is Easy

Fully Automated Operation
The FilmArray reagents pouch contains all the required reagents for sample preparation, reverse transcription-PCR, PCR, and detection in a freeze-dried, room temperature stable format. Prior to a run, the operator injects hydration solution and the unknown sample into the pouch. The FilmArray instrument does the rest. First, the FilmArray extracts and purifies all nucleic acids from the unknown sample. Next, the FilmArray performs a nested multiplex PCR. During the first-stage PCR, the FilmArray performs a single, large volume, massively multiplexed reaction. Last, individual singleplex second-stage PCR reactions detect the products from the first stage PCR. Using endpoint melting curve data, the FilmArray software automatically generates a result for each target.
FilmArray Instrument and Pouch Specifications
| Instrument Specifications |
| Sample Handling |
Sample Types: Swab, powder, liquid, culture, soil
Sample Volume: 250 µL |
| Reagents |
Freeze-dried in durable plastic pouches
Room temperature storage |
| Instrument Specifications |
Power Requirements: 90-264 VAC, 10 A
Size: 25.4 x 39.3 x 16.5 cm (10 x 15.5 x 6.5 in.)
Weight: 9 kg (20 lb.) |
| Performance Parameters |
Hands on time: Approx. 2 minutes
Raw sample to results: 1 hour |
| Environmental Specification |
Operating: 15 °C to 30 °C at 20 to 80% humidity
Storage: -30 °C to 65 °C |
| Desktop Software |
Windows-based instrument control and data analysis software
Barcode reader for data input
Automated qualitative analysis and reporting
Separate advanced analysis software |
| The Following Assays are Contained in the FilmArray BioThreat Panel |
- Bacillus anthracis, 3 Targets
- Brucella melitensis, 2 Targets
- Burkholderia, 2 Targets
- Clostridium botulinum
- Coxiella burnetii, 2 Targets
- Ebola virus (Zaire)
- EEE virus
- F. tularensis, 2 Targets
|
- Marburg virus, 2 Targets
- Ricinus communis
- Rickettsia prowazekii, 2 Targets
- Staphylococcus aureus
- Variola virus
- VEE virus, 2 Targets
- WEE virus
- Yersinia pestis, 2 Targets
- Orthopox virus, 2 Targets
|
| |
| The Following Assays are Contained in the FilmArray Respiratory Panel: |
FDA Cleared |
|
- Adenovirus
- Coronavirus HKU1
- Coronavirus NL63
- Influenza A
- Influenza A H1
- Influenza A H1 2009
- Influenza A H3
- Influenza B
|
- Metapneumovirus
- Parainfluenza 1
- Parainfluenza 2
- Parainfluenza 3
- Parainfluenza 4
- Respiratory Syncytial Virus
- Rhinovirus / Enterovirus
|
| Ordering Information |
| |
Catalog No. |
FilmArray BioDefense System
|
FLM1-ASY-0108 |
BioThreat Pouch Kit - 6 Pouches per Kit
|
RFIT-ASY-0094 |
Respiratory Pouch Kit - 30 pouches per Kit
|
RFIT-ASY-0001 |
|
|
New Product: FilmArray Instrument |
BioFire Diagnostic is proud to announce the FilmArray, the future of automated clinical and diagnostic sample
detection.
For Research Use Only. Not for use in diagnostic procedures.

|

View the global state of infectious diseases and their effect on human and animal health with this up-to-date interactive world map.
>> Click here for details |
|